{"id":36116,"date":"2026-10-03T12:50:58","date_gmt":"2026-10-03T10:50:58","guid":{"rendered":"https:\/\/www.archieinteriors.com\/?p=36116"},"modified":"2026-11-13T14:23:55","modified_gmt":"2026-11-13T13:23:55","slug":"energy-retrofit-existing-buildings","status":"publish","type":"post","link":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/","title":{"rendered":"Energy Retrofit of Existing Buildings: What Really Changes in the Space"},"content":{"rendered":"<p>In a 1960s building, the retrofit project starts from a seemingly simple floor plan. Then the first checks come in: insulation changes wall thicknesses, new building systems need routes, and replacement windows change the relationship between wall and opening. What looks on paper like an energy-efficiency upgrade also becomes a matter of <strong>architectural geometry<\/strong>.<\/p>\n<p>If you are working on an existing building, an energy retrofit means considering from the very start what the work will physically leave behind. Not just the expected performance, but centimeters, plant volumes, service routes, floor and ceiling levels, openings and junction details.<\/p>\n<h2>At a glance: four checks before you finalize the design<\/h2>\n<p>Before you sign off on an <strong>energy retrofit<\/strong> solution, check four things:<\/p>\n<ul>\n<li>how much space the layers added to the building envelope will take up;<\/li>\n<li>where the new service runs will go and which rooms they will cross;<\/li>\n<li>how windows, reveals, sills and openings will change;<\/li>\n<li>which works must be coordinated before construction begins.<\/li>\n<\/ul>\n<p>So the question is not only which technology to adopt, but <strong>what that technology demands of the building<\/strong>.<\/p>\n<h2>Insulation is more than a layer on the wall<\/h2>\n<p>Adding insulation changes the construction section. If you insulate from the outside, the extra thickness projects toward the facade and has to be coordinated with sills, thresholds, balconies, downspouts, decorative features and other existing details.<\/p>\n<p>If you insulate from the inside, those centimeters are taken away from the rooms. The effect goes beyond the theoretical floor area: the position of finishes, the depth of window reveals and the relationship between walls and furniture all change. In some cases you also need to work out how to treat <strong>thermal bridges<\/strong> at points of discontinuity.<\/p>\n<p>There is no single correct thickness independent of the building. It has to be assessed together with the existing wall build-up, the properties of the materials, the geometry and the way the rooms are used.<\/p>\n<p>The main constraint in an energy retrofit of an existing building is often <strong>the compatibility between the energy solution and what the building actually allows you to change<\/strong>.<\/p>\n<h2>New building systems bring new volumes<\/h2>\n<p>The same care is needed when you upgrade mechanical systems. An outdoor unit, a heat pump, ductwork, pipework or control systems are not abstract elements in a technical drawing: they have physical dimensions and require access, connections and maintenance clearances.<\/p>\n<p>You need to know where the units will sit, which routes will be required and where the service runs will pass before you design dropped ceilings, furring walls and other interior elements.<\/p>\n<p>A dropped ceiling designed without taking ductwork into account, for example, may end up at a different height from the one originally planned. In a room with a low ceiling, a few centimeters can become a design issue, not a detail to sort out on site.<\/p>\n<p>The same goes for openings: if a new service layout passes through a wall, you need to check in advance for doors, windows, structural elements and finishes.<\/p>\n<h2>Windows: the issue is the junction, not just the frame<\/h2>\n<p>Replacing a window means intervening at the point where <strong>envelope and opening meet<\/strong>. That is why comparing the size of the new window with the old one is not enough.<\/p>\n<p>You need to check the depth of the frame, its position within the wall, the reveals, the sill and the continuity of insulation around the opening. If the work changes the geometry of the opening, the building and health regulations that apply to the project also come into play.<\/p>\n<p>Under Italian rules, for example, the required ratio between window area and floor area for daylight and natural ventilation (the so-called <em>rapporti aeroilluminanti<\/em>) is not a check to run automatically for every replacement: it becomes relevant when the work actually changes the conditions of the opening or the rooms involved. In any case, the design must be verified against the regulations that apply to the specific project.<\/p>\n<p>That is why the <strong>window junction<\/strong> should be designed together with the envelope, not added as a final detail.<\/p>\n<h2>Design stage or construction site? Where decisions should be made<\/h2>\n<p>If a decision about dimensions or systems is postponed until construction, the room for adjustment shrinks. If it is defined in the design documents, it can be coordinated with the other parts of the project.<\/p>\n<table>\n<thead>\n<tr>\n<th>Aspect<\/th>\n<th>Decision made at design stage<\/th>\n<th>Decision made on site<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cost<\/td>\n<td>You can compare solutions and work items before placing orders<\/td>\n<td>Adjustments may alter work that was already planned<\/td>\n<\/tr>\n<tr>\n<td>Schedule<\/td>\n<td>You can coordinate deliveries and the sequence of works<\/td>\n<td>Clashes may require changes to the schedule<\/td>\n<\/tr>\n<tr>\n<td>Reversibility<\/td>\n<td>You can assess access and the potential for future changes<\/td>\n<td>Completed solutions may be harder to correct<\/td>\n<\/tr>\n<tr>\n<td>Energy performance<\/td>\n<td>You can check how envelope and systems interact<\/td>\n<td>The available alternatives may be more limited<\/td>\n<\/tr>\n<tr>\n<td>Documentation<\/td>\n<td>You can update drawings, cost estimates and specifications<\/td>\n<td>Changes have to be incorporated during construction<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The difference is not just organizational. <strong>Deciding early means designing the relationships between elements<\/strong>, whereas deciding during construction often means adapting one element to conditions that are already fixed.<\/p>\n<h2>Who sizes the retrofit and who verifies the results?<\/h2>\n<p>When a retrofit involves the envelope, building systems and energy management, you need to distinguish between designing the individual works and verifying the performance the project is expected to deliver.<\/p>\n<p><strong>UNI CEI 11352:2014<\/strong>, the Italian standard currently in force for energy service companies, sets out the requirements and capabilities of ESCOs, including organizational, diagnostic, design, management and financial skills. Certification therefore attests that a company meets requirements for organizing and delivering energy services; on its own, it is not a guarantee of the outcome of any specific project.<\/p>\n<p>This is where <a href=\"https:\/\/www.percaya.it\/esco-energy-service-company\/\">Percaya S.r.l.<\/a> comes in. On its website, the company presents itself as a <strong>UNI CEI 11352-certified ESCO<\/strong> and describes a process based on analyzing the initial data, the condition of the building and its systems, the objectives and how results will be verified. The company itself specifies that certification does not automatically amount to an energy audit, a quote or a guarantee of results.<\/p>\n<h2>Questions to ask before ordering materials<\/h2>\n<h3>How much space should I allow for insulation?<\/h3>\n<p>You cannot work it out from the thickness of the material alone. You need to consider the full wall build-up and check where the new layer meets windows, thresholds, services, walls and other building elements.<\/p>\n<h3>When does a new system need extra space?<\/h3>\n<p>Every piece of equipment has different dimensions, connections and access requirements. Before designing dropped ceilings or plant rooms, you need to know the equipment footprint, service routes and maintenance clearances.<\/p>\n<h3>Does replacing windows always reduce usable floor area?<\/h3>\n<p>Not necessarily. You need to distinguish a simple window replacement from work that alters reveals, openings, finishes or the interior layout. If the configuration of the room changes, the specific design and regulatory implications must be checked.<\/p>\n<h3>What do I need before ordering materials?<\/h3>\n<p>At a minimum, you should have updated drawings of the planned works, verified dimensions, details of the construction junctions and a record of clashes with building systems. That way you can compare what you order with what the project actually requires.<\/p>\n<h2>Before signing off on an energy retrofit, look at the building in section<\/h2>\n<p>Before giving the go-ahead to a retrofit, try reading the project not only in plan but also through its <strong>sections and connections<\/strong>. Ask where each new layer will end, where the service runs will go, how the junctions around openings will be resolved and which levels will change.<\/p>\n<p>If these answers are not yet defined, the project is not ready to become a materials order. This is precisely the stage at which you can still correct a solution without having to adapt the building to work that has already begun.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In a 1960s building, the retrofit project starts from a seemingly simple floor plan. Then the first checks come in: insulation changes wall thicknesses, new building systems need routes, and replacement windows change the relationship between wall and opening. What looks on paper like an energy-efficiency upgrade also becomes a matter of architectural geometry. If&#8230;<\/p>\n","protected":false},"author":24,"featured_media":20740,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"sintesi_articolo":"","footnotes":""},"categories":[334,354],"tags":[],"top_category":[],"class_list":["post-36116","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-architecture","category-construction"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Energy Retrofit of Existing Buildings: What Changes<\/title>\n<meta name=\"description\" content=\"An energy retrofit of existing buildings changes wall thickness, ceiling heights and openings. What to check at design stage before ordering any materials.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Energy Retrofit of Existing Buildings: What Changes\" \/>\n<meta property=\"og:description\" content=\"An energy retrofit of existing buildings changes wall thickness, ceiling heights and openings. What to check at design stage before ordering any materials.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/\" \/>\n<meta property=\"og:site_name\" content=\"Archi &amp; Interiors\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-03T10:50:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-13T13:23:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Giulia Salvadori\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Giulia Salvadori\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/\"},\"author\":{\"name\":\"Giulia Salvadori\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#\/schema\/person\/9162e8cf6786d0e31be986f10417520f\"},\"headline\":\"Energy Retrofit of Existing Buildings: What Really Changes in the Space\",\"datePublished\":\"2026-10-03T10:50:58+00:00\",\"dateModified\":\"2026-11-13T13:23:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/\"},\"wordCount\":1300,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg\",\"articleSection\":[\"Architecture\",\"Construction\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/\",\"url\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/\",\"name\":\"Energy Retrofit of Existing Buildings: What Changes\",\"isPartOf\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg\",\"datePublished\":\"2026-10-03T10:50:58+00:00\",\"dateModified\":\"2026-11-13T13:23:55+00:00\",\"description\":\"An energy retrofit of existing buildings changes wall thickness, ceiling heights and openings. What to check at design stage before ordering any materials.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage\",\"url\":\"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg\",\"contentUrl\":\"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg\",\"width\":1200,\"height\":800,\"caption\":\"Brick building with a facade punctuated by windows, a project by FTA Filippo Taidelli Architetto in Milan\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.archieinteriors.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Energy Retrofit of Existing Buildings: What Really Changes in the Space\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#website\",\"url\":\"https:\/\/www.archieinteriors.com\/en\/\",\"name\":\"Archi & Interiors\",\"description\":\"Archi &amp; Interiors Magazine\",\"publisher\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.archieinteriors.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#organization\",\"name\":\"Archi & Interiors\",\"url\":\"https:\/\/www.archieinteriors.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2024\/07\/cropped-customcolor_logo_customcolor_background.png\",\"contentUrl\":\"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2024\/07\/cropped-customcolor_logo_customcolor_background.png\",\"width\":937,\"height\":550,\"caption\":\"Archi & Interiors\"},\"image\":{\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#\/schema\/person\/9162e8cf6786d0e31be986f10417520f\",\"name\":\"Giulia Salvadori\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.archieinteriors.com\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ef1b2a33aaca914148955e6ae4907b5e94e92d2108a69cf832fe1def926e301b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ef1b2a33aaca914148955e6ae4907b5e94e92d2108a69cf832fe1def926e301b?s=96&d=mm&r=g\",\"caption\":\"Giulia Salvadori\"},\"url\":\"https:\/\/www.archieinteriors.com\/en\/author\/giulia-salvadori\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Energy Retrofit of Existing Buildings: What Changes","description":"An energy retrofit of existing buildings changes wall thickness, ceiling heights and openings. What to check at design stage before ordering any materials.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/","og_locale":"en_US","og_type":"article","og_title":"Energy Retrofit of Existing Buildings: What Changes","og_description":"An energy retrofit of existing buildings changes wall thickness, ceiling heights and openings. What to check at design stage before ordering any materials.","og_url":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/","og_site_name":"Archi &amp; Interiors","article_published_time":"2026-10-03T10:50:58+00:00","article_modified_time":"2026-11-13T13:23:55+00:00","og_image":[{"width":1200,"height":800,"url":"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg","type":"image\/jpeg"}],"author":"Giulia Salvadori","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Giulia Salvadori","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#article","isPartOf":{"@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/"},"author":{"name":"Giulia Salvadori","@id":"https:\/\/www.archieinteriors.com\/en\/#\/schema\/person\/9162e8cf6786d0e31be986f10417520f"},"headline":"Energy Retrofit of Existing Buildings: What Really Changes in the Space","datePublished":"2026-10-03T10:50:58+00:00","dateModified":"2026-11-13T13:23:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/"},"wordCount":1300,"commentCount":0,"publisher":{"@id":"https:\/\/www.archieinteriors.com\/en\/#organization"},"image":{"@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg","articleSection":["Architecture","Construction"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/","url":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/","name":"Energy Retrofit of Existing Buildings: What Changes","isPartOf":{"@id":"https:\/\/www.archieinteriors.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage"},"image":{"@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage"},"thumbnailUrl":"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg","datePublished":"2026-10-03T10:50:58+00:00","dateModified":"2026-11-13T13:23:55+00:00","description":"An energy retrofit of existing buildings changes wall thickness, ceiling heights and openings. What to check at design stage before ordering any materials.","breadcrumb":{"@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#primaryimage","url":"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg","contentUrl":"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2026\/05\/fta-filippo-taidelli-architect-milan-energy-redevelopment.jpg","width":1200,"height":800,"caption":"Brick building with a facade punctuated by windows, a project by FTA Filippo Taidelli Architetto in Milan"},{"@type":"BreadcrumbList","@id":"https:\/\/www.archieinteriors.com\/en\/energy-retrofit-existing-buildings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.archieinteriors.com\/en\/"},{"@type":"ListItem","position":2,"name":"Energy Retrofit of Existing Buildings: What Really Changes in the Space"}]},{"@type":"WebSite","@id":"https:\/\/www.archieinteriors.com\/en\/#website","url":"https:\/\/www.archieinteriors.com\/en\/","name":"Archi & Interiors","description":"Archi &amp; Interiors Magazine","publisher":{"@id":"https:\/\/www.archieinteriors.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.archieinteriors.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.archieinteriors.com\/en\/#organization","name":"Archi & Interiors","url":"https:\/\/www.archieinteriors.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.archieinteriors.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2024\/07\/cropped-customcolor_logo_customcolor_background.png","contentUrl":"https:\/\/www.archieinteriors.com\/wp-content\/uploads\/2024\/07\/cropped-customcolor_logo_customcolor_background.png","width":937,"height":550,"caption":"Archi & Interiors"},"image":{"@id":"https:\/\/www.archieinteriors.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.archieinteriors.com\/en\/#\/schema\/person\/9162e8cf6786d0e31be986f10417520f","name":"Giulia Salvadori","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.archieinteriors.com\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ef1b2a33aaca914148955e6ae4907b5e94e92d2108a69cf832fe1def926e301b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ef1b2a33aaca914148955e6ae4907b5e94e92d2108a69cf832fe1def926e301b?s=96&d=mm&r=g","caption":"Giulia Salvadori"},"url":"https:\/\/www.archieinteriors.com\/en\/author\/giulia-salvadori\/"}]}},"_links":{"self":[{"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/posts\/36116","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/comments?post=36116"}],"version-history":[{"count":1,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/posts\/36116\/revisions"}],"predecessor-version":[{"id":36302,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/posts\/36116\/revisions\/36302"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/media\/20740"}],"wp:attachment":[{"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/media?parent=36116"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/categories?post=36116"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/tags?post=36116"},{"taxonomy":"top_category","embeddable":true,"href":"https:\/\/www.archieinteriors.com\/en\/wp-json\/wp\/v2\/top_category?post=36116"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}